Multi-parameter Controller
Image 1
Image 2

Description

The UVCON-EQMS  Multi-Parameter Controller is a compact, microprocessor-based analytical controller designed for continuous online monitoring and control of multiple water quality parameters in industrial and utility applications. It provides reliable, accurate, and real-time measurement for critical process and utility systems.

The controller supports connection to a wide range of analytical sensors and transmitters, enabling simultaneous monitoring of key parameters such as pH, ORP, conductivity, resistivity, TDS, dissolved oxygen, and temperature, depending on configuration. Its modular design allows flexible system integration to meet specific application requirements.

The UVCON-EQMS  features a high-resolution display with intuitive menu navigation for easy configuration, calibration, and diagnostics. Multiple configurable analog outputs (4–20 mA) and relay outputs enable seamless integration with PLCs, DCS, SCADA systems, and control panels for monitoring, alarm, and control functions.

Built for industrial environments, the UVCON-EQMS  offers robust electrical isolation, stable signal processing, and long-term measurement reliability. It supports password-protected access, alarm logging, and fail-safe operation, ensuring data integrity and operational safety.

The UVCON-EQMS  Multi-Parameter Controller is suitable for applications in power plants, water and wastewater treatment, chemical and process industries, refineries, pharmaceuticals, food & beverage, and utility monitoring systems, providing a dependable solution for centralized analytical control.

Features

• The UVCON-EQMS series multi-channel digital universal controller realizes measurement by connecting various types of sensors for detecting physical, chemical, biological.

• Connect 4 or 8 different types of digital sensors at the same time, and can display the detected or calculated measurement data of all connected sensors

  UVCON-EQMS  requires these authorized sensors to upload the detected data in a special encrypted communication way to ensure that the controller can collect high-precision data more stably.

• Display the collected data on the display screen of the controller in real time, which is convenient for users to read.

• Meet a variety of installation methods, and can also provide installation accessories.

Specifications:

ModelUVCON-EQMS UVCON-EQMS-A8
Measure Channel1~4 channels input1~8 channels input
Measure InformationRelated to sensors-
Measure InformationRelated to sensors-
Display Screen128*64 pixel, 3.2-inch black and white graphic LCD display, backlight and contrast can be adjusted-
Display Screen128*64 pixel, 3.2-inch black and white graphic LCD display, backlight and contrast can be adjusted-
Instrument OperationPET key panel, 8 keys-
System LanguageEnglish-
Power-off ProtectionAll setting parameters of the instrument are power-off protection, andthedata is retained indefinitely.-
Time DisplayYear/Month/day, hour/minute/second-
History LogsRecord 7800 history data, support data download The recording interval can be set between 1~999 minutes-
Menu PasswordOperation authority management, six-digit password settings-
Relay OutputWash control, max. Load 3A/250V AC-
Output extension typeRelays, current, communication(Optional)-
Digital CommunicationCommunication interface: 2-wire RS485 interface Communication protocol: Modbus RTU JSON-
Protection GradeIP66-
Working Temperature0~60℃, RH <95% (no condensation)-
Storage Temperature-20~70℃, RH<55% (no condensation)-
Instrument Dimension144*144*120mm(hole size: 138*138mm)-
Installation MethodPanel, wall-mounted, pipe clamping-
Housing MaterialEnhanced ABS-
Power SupplyAC: 100~240V 50/60Hz or DC: 18~36V-
Consumption24W
Digital COD Sensor
Image 1

Description

The total amount of organic pollutants in the water can be measured by measuring the degree of absorption of these organic substances to 254nmwavelength ultraviolet light.

The COD 351 digital sensor adopts two light sources, one 254nm ultraviolet light, and one turbidity compensation, which can automatically eliminate the interference of suspended substances in the water, so as to achieve more stable and reliable measurement.

Features

• RS-485 output, support Modbus

• No reagents, no pollution, environmentally friendly

• Can measure COD, TOC, turbidity and temperature

• Automatically compensate for turbidity interference

• With self-cleaning brush and the maintenance cycle is longer

Specifications:

ModelUVCON-COD-LUVCON-COD-H
Measuring PrincipleUV254 Absorption Method-
Optical path6mm2mm
Measuring RangeCOD: 0.75~500mg/LCOD: 1~1500mg/L
Measuring RangeTOC: 0.3~200mg/LTOC: 0.4~600mg/L
ResolutionCOD: 0.01mg/L TOC: 0.1mg/L
Accuracy± 3% of the measurement + 0.5mg/L
Related MeasurementTU: 0~300NTU accuracy: ± 5%TU: 0~1000NTU accuracy: ±5%
Response Time>1min-
Operating Tempe0~45℃ (does not freeze)-
Storage Temp -10~60℃-
Calibration MethodStandard solution-
Protection GradeIP68-
Flow Ratenot depend on-
PowerDC 12V~24V-
CommunicationRS485, Modbus RTU protocol-
DimensionDiameter 60mm, length 215mm-
Lead InterfaceM16-
InstallationInvestment, 1 inch NPT pipe thread-
Shell Material316L stainless steel+POM-
Power ConsumptionNormal measurement: 0.1W;-
Power ConsumptionAutomatic cleaning by mechanical wiper: 3W;-
Power ConsumptionAbnormal jamming of mechanical wiper: 4.5W-
Weight720g-
Digital TSS/Turbidity Sensor
Image 1
Image 2

Features

 • Based on the infrared absorption and scattering light method

• Use ISO7027 method to continuously and accurately determine turbidity and suspended solids in water

• LED infrared scattering light source (850nm), stable wavelength, stable data

• Reliable performance, simple installation and calibration

• Self-diagnostic function, built-in humidity sensor and a light source detector

• Internal storage of calibration data, support offline calibration, plug and play

• Standard Modbus protocol, support access to standard industrial control system

Specifications:

ModelUVCON-TUR-ZUVCON-TUR-H
Electrical IsolationElectrical isolated communication and power interfaces-
Measuring Technology Infrared scattering principle-
Measuring RangeTurbidity: 0.01~1000NTUTurbidity: 0.01~4000NTU
Measuring RangeSuspended solids: 1~3000mg/LSuspended solids: 1~3000mg/L
Resolution0.01NTU/1mg/L0.01NTU/1mg/L
AccuracyBetter than 5% of measured value or 0.3NTU, take the larger oneBetter than 5%of measuredvalueor1NTU, take the larger one
CommunicationRS485 MODBUS-RTU-
Related ConfigurationHumidity alarm-
Response TimeT90<15s-
Calibration MethodMulti-point calibration; Contrast Offset; Factor offset-
Work Pressure≤4Bar-
Sample Flow RateNot dependent-
Operating Temp0~50℃ (does not freeze)-
Storage Temp-10~60℃ (does not freeze)-
Shell Material316L stainless steel-
DimensionDiameter: 52mm length: 260 mm-
Mounting ThreadHorizontal installation, dedicated 90° mounting accessories-
Lead interfaceSplit M16 connector-
Protection GradeIP68-
Power Supply9~24V DC-
Power Consumption0.6W-
Weight700g-
CableStandard 5 meters (other length can be customized)-
Digital Ph/ORP Senor
Image 1

Features

• Compact all-in-one design

• Support handheld devices and in-situ applications

• Large capacity reference, long service life

• 1 inch NPT mounting thread for flexible installation

• Internal storage of calibration data

• Support offline calibration, on-site plug and play

• Optional cleaning connector for underwater cleaning

• Standard Modbus protocol, support access to standard industrial control system

Specifications:

ModelUVCON-PHUVCON-ORP
Electrical IsolationElectrical isolated communication and power interfaces-
Measuring ObjectpHORP
Measuring TechnologyElectrochemical glass electrodeElectrochemical platinum electrodes
Measuring RangepH: 0~14pH TEMP.: 0~50℃ORP: ±2000mV TEMP.: 0~50℃
Resolution0.01pH / 0.1℃±1mV / 0.1℃
Accuracy0.1% of the range or ±0.02pH, take the larger one; Temp.: ±0.5℃0.1% of the range or ±2mV, take the larger one; Temp.: ±0.5℃
CommunicationRS485 MODBUS-RTU-
Temp. UnitAutomatic Temp. compensationTemp. measurement
Response TimeT90 < 10s-
Calibration MethodZero position calibration and slope calibration-
Work Pressure0~4Bar-
Sample Flow Rate0.5m/s ≥ flow rate ≥ 0.001m/s-
Operating Temp0~50℃ (does not freeze)-
Storage Temp0~60℃ (does not freeze)-
Shell MaterialPPS-
DimensionDiameter: 35mm Length: 220 mm (protective claw included)-
Mounting Thread1 inch NPT at both ends; immersed or piped installation-
Lead interfaceIntegral or split M16 connector-
Protection GradeIP68-
Power Supply9~24V DC-
Power Consumption0.2W-
Weight200g-
CableStandard 5 meters (other length can be customized)-